Column Load Ballpark
Floors + tributary area → axial load on a column
Category: Engineering
What you enter
- Floors carried above (incl. roof)
- Tributary area per floor (sq ft)
- Building use: Residential · ~12 kN/m² per floor, Office / commercial · ~14 kN/m², Heavy storage / godown · ~17.5 kN/m²
An example
With the starting values (Floors carried above (incl. roof): 4; Tributary area per floor (sq ft): 160; Building use: Residential · ~12 kN/m² per floor), it gives:
- Service axial load: 713 kN (≈ 73 tonnes)
- Factored design load (1.5×): 1,070 kN
- Indicative column size (M25, ~1% steel): ≈ 300 × 300 mm
Good to know
Tributary area = the floor patch each column carries (≈ span/2 all around). Loads accumulate downward — the ground-storey column carries every floor above it, which is why columns get bigger and more heavily reinforced toward the bottom, and why chasing or trimming a ground-floor column is never OK. Ballpark per IS 875 loads; real design needs analysis.
Sources
- IS 875 (Parts 1 and 2):1987 (loads)
Checked 7 Oct 2026, pending our team’s sign-off.
Read the guide
Free, instant and indicative: a starting point for our engineers’ estimate, not a substitute for one.