Is my building earthquake-ready? A Zone III self-check
Kolkata sits in Seismic Zone III on soft alluvial soil. Answer five quick questions about your building's age, height, ground floor and condition for a first read on where it stands — and which strengthening measures typically help.
Kolkata is not one of India's most active earthquake areas, but it is not a quiet one either. It lies in Seismic Zone III under IS 1893 (Part 1):2016, it stands on deep, soft delta soils that can amplify shaking, and it has felt earthquakes centred hundreds of kilometres away, in the Himalaya, Myanmar and the Bay of Bengal. Most of its buildings were designed with little thought for earthquakes, and many have had floors, tanks and open parking added since.
This guide explains what Zone III means, why soft ground matters, the features that make a building vulnerable, a simple self-check you can do, what an engineer adds, the common ways buildings are strengthened, and what to do before and during an earthquake. Our Seismic Readiness tool in the Lab gives a first read for your building, our guide to earthquakes and Kolkata covers the background, and our structural audit guide explains a full assessment.
What Zone III means
IS 1893 (Part 1):2016 divides India into four seismic zones, II to V, with a zone factor for each that sets the design ground motion. Kolkata and much of southern West Bengal are in Zone III, with a zone factor of 0.16, which the code treats as moderate. A 2025 edition of the code with a revised zone map was withdrawn in March 2026, so the 2016 edition and its zones are the ones in force.
Moderate does not mean safe by default. Zone III asks for buildings to be designed and detailed for earthquake forces, and for reinforced concrete frames to follow the ductile detailing of IS 13920:2016. A building designed without them can be badly damaged by shaking that a well-detailed building would ride out.
Why soft ground matters
Earthquake waves change as they pass through soil. Deep, soft deposits like Kolkata's clays and silts can amplify the shaking at some frequencies, and lengthen it. Taller buildings on such ground can be shaken harder than the same building on rock. Loose, saturated sands, found in parts of the delta and in filled ground, can lose their strength when shaken, a process called liquefaction, which lets foundations sink or tilt. IS 1893 takes soil type into account in design; an engineer's assessment of your building does too.
Features that make a building vulnerable
| Feature | Why it matters |
|---|---|
| An open ground floor for parking, with walls above | A soft storey: the movement concentrates in the open floor's columns |
| Floors added on top | More mass, on columns and foundations designed for fewer floors |
| Heavy water tanks or rooms on the roof | Mass high up, which increases the sway |
| Columns that are small, or plain bars with few ties | Little strength and ductility where it is most needed |
| Floating columns that stand on beams | Load paths that break under shaking |
| Strongly irregular shapes, deep L or T plans | Twisting and stress at the corners |
| Unreinforced brick walls and parapets | Brittle walls, and parapets and chimneys that fall onto the street |
| Buildings touching their neighbours with no gap | Pounding between buildings that sway differently |
| Visible damage: cracks, spalling, rusted steel | A building already weakened before any earthquake |

A simple self-check
- Find out when the building was built, and whether it was designed by an engineer and to which codes.
- Count the floors, and note any floors, rooms or tanks added later.
- Look at the ground floor: open for parking, shops with wide fronts, or walled like the floors above.
- Look at the columns: their size, and whether any start from a beam rather than the ground.
- Look for cracks, spalling concrete and rusted steel, especially in the ground floor columns and beams.
- Look at the roof: water tanks, rooms and parapets.
- Look at the neighbours: whether the building touches them, and whether they are taller or shorter.
- Put your answers into our Seismic Readiness tool for a first read, then decide whether an engineer should look.
What an engineer adds
A self-check shows where to look. An engineer's evaluation, following IS 15988:2013, the Indian guidelines for the seismic evaluation and strengthening of existing reinforced concrete buildings, goes further: a survey of the structure and its condition, tests of the concrete and steel, a check of the soil, and an analysis of how the building would carry earthquake forces. It ends with a report that says where the building is weak, how weak, and what would strengthen it, in order of priority.
How buildings are strengthened
- Jacketing weak columns and beams with reinforced concrete, steel or fibre wraps; our column jacketing guide explains it.
- Adding shear walls or steel bracing, often in the open ground floor, to stiffen a soft storey.
- Filling some ground floor bays with walls designed to carry load, where parking allows.
- Removing or lightening added mass: rooms and tanks on the roof, or moving tanks over column lines.
- Tying brick walls together with bands or ties, and securing parapets and chimneys.
- Repairing rusted steel and spalled concrete before anything else.
- Separating buildings that would pound, where it is possible.
Older brick houses
Many Kolkata houses built before the 1960s have thick brick walls in lime mortar carrying timber or concrete floors, and no concrete frame. In an earthquake, such walls can crack, separate at the corners and, at worst, fall outward, especially where floors are not tied to the walls, openings are large and close to corners, or floors have been added in concrete on top. IS 4326 and the guidelines for improving the earthquake resistance of existing masonry buildings describe the remedies: bands or ties that hold the walls together at floor and roof level, strengthening of corners and openings, and lighter roofs where the old ones are heavy.
These houses also often carry decades of damp and repairs that weaken their walls. A survey of their condition comes first, then strengthening matched to what the walls can bear. Removing walls inside such a house, for open-plan rooms, takes away exactly what holds it up; our load-bearing walls guide explains the checks.
Before and during an earthquake
Some steps cost little and help everyone. Fix tall cupboards, shelves and water heaters to the walls. Keep heavy things low. Know where the gas cylinder valve and the main electrical switch are. Agree a meeting place outside, away from buildings and wires.
During shaking, the advice from the National Disaster Management Authority is to drop, cover and hold on: get under a sturdy table, cover your head and hold on until the shaking stops. Keep away from windows, glass and things that can fall. Do not use lifts. Do not run outside while the shaking lasts; most injuries come from falling objects near the building. When it stops, leave calmly by the stairs and check for damage, gas leaks and fires.
Questions people ask
Is Kolkata at risk of earthquakes?
Kolkata is in Seismic Zone III under IS 1893 (Part 1):2016, a moderate zone, and its soft soils can amplify shaking. Buildings here should be designed and detailed for earthquakes.
Is your building earthquake-safe?
A self-check and our Seismic Readiness tool give a first read. Only an engineer's evaluation, with a survey and analysis, can say how your building would perform.
Why are buildings with ground floor parking a concern?
An open ground floor under walled floors is a soft storey: in an earthquake the movement concentrates there. The code asks for it to be designed for much larger forces.
Can an old building be made safer?
Usually yes: by jacketing weak columns, adding shear walls or bracing, removing added mass and repairing damage. An engineer's evaluation decides what is needed.
Which edition of the earthquake code applies?
IS 1893 (Part 1):2016. A 2025 edition was withdrawn in March 2026, so the 2016 edition and its zones are in force.
What should you do during an earthquake?
Drop, cover and hold on under a sturdy table, away from windows and falling objects. Do not use lifts or run outside while it is shaking.
Try it in our Lab: Seismic Readiness
Sources
- IS 1893 (Part 1):2016 Criteria for Earthquake Resistant Design of Structures (Bureau of Indian Standards) (checked 15 Nov 2026)
- IS 15988:2013 Seismic Evaluation and Strengthening of Existing Reinforced Concrete Buildings, Guidelines (Bureau of Indian Standards) (checked 15 Nov 2026)
- IS 13920:2016 Ductile Design and Detailing of Reinforced Concrete Structures Subjected to Seismic Forces (Bureau of Indian Standards) (checked 15 Nov 2026)
- National Disaster Management Authority: earthquakes, do's and don'ts (checked 15 Nov 2026)