Delta Structures

Staircase rules — riser, tread and headroom the code requires

A comfortable, legal stair for a home: risers 150–190mm, treads 250–300mm, no more than 12 risers between landings, at least 2.2m (7 ft 3 in) of clear headroom, and every riser in a flight identical. The formula that works: 2×riser + tread = 580–640mm. Steep, uneven site-built stairs are one of the most common injuries-in-waiting in small buildings.

Your body memorises the first two steps and repeats the motion blind. A single odd riser mid-flight is a trip hazard precisely because you stop looking.

A staircase is used thousands of times a year, often in the dark, often carrying something, often by children and older people. Its comfort and safety depend on a handful of measurements: the height of each step, the depth of each tread, the clear width, the headroom and the handrail. Get them right and nobody notices the stair. Get one of them wrong, and especially let one step differ from the others, and someone falls.

This guide explains the parts of a stair, comfortable proportions, what the building rules and codes ask for, headroom and where stairs lose it, why every step must be the same, landings, handrails and balusters, stairs in buildings of flats and fire escape, the structure behind the stair, and the checks on the drawing and on site. Our Staircase Designer in the Lab lets you walk up a stair with your own measurements, and our Staircase Calculator works out the risers and treads.

The parts of a stair

PartWhat it is
RiserThe vertical height of one step
TreadThe horizontal depth of one step, where the foot goes
GoingThe tread measured from the edge of one step to the edge of the next
NosingThe front edge of a tread, sometimes projecting over the riser below
FlightA run of steps between landings
LandingA level platform between flights or at the top and bottom
WaistThe thickness of a concrete stair slab under the steps
HeadroomThe clear height above the stair to the nearest ceiling, beam or slab
Flights and landings of a stair at the Birla Industrial & Technological Museum, Kolkata
Flights and landings of a stair at the Birla Industrial & Technological Museum, Kolkata. Photo: Biswarup Ganguly, CC BY 3.0, via Wikimedia Commons

Comfortable proportions

A stair is comfortable when its steps match the length of a natural stride. The usual working rule is that twice the riser plus the tread should come to about 580 to 640 mm. For homes, risers of about 150 to 190 mm with treads of about 250 to 300 mm fall inside that band. Lower risers with deeper treads feel easy and suit older people; steep, high risers with shallow treads are tiring going up and dangerous coming down.

Our Staircase Calculator takes your floor-to-floor height and suggests the number of risers and the tread that fit, and our Staircase Designer lets you try them in 3D before anything is built.

What the rules ask

The building rules set minimums that a stair must meet; good design usually does better. The Model Building Bye-Laws, 2016, ask for a clear width of at least 1.0 m for stairs in homes, with 0.75 m allowed only in a two-storey row house (clause 4.17.2), and at least 2.2 m of clear headroom (clause 4.17.4.2). In Kolkata, the KMC Building Rules, 2009, set the stair widths for buildings with flats in rule 127, rising from 1.0 m to 1.5 m as buildings get taller, with landings at least as wide as the stair. The National Building Code, 2016, added the rules for stairs as fire exits in taller and larger buildings. Its successor, Part F of the National Building Construction Standards 2026, advises for residential buildings over 24 m or 750 m² a floor: risers of at most 175 mm in one- or two-family homes and 150 mm in others, treads of at least 250 mm, and no more than 15 risers a flight (clause 4.4.2.4.3.1).

  • Risers between about 150 and 190 mm, the same in every step of a flight.
  • Treads of at least about 250 mm for homes.
  • No more than about twelve to fifteen risers in a flight before a landing, as the applicable rule sets.
  • Clear width at least 1.0 m in homes, and as KMC rule 127 sets for buildings with flats.
  • Clear headroom at least 2.2 m everywhere on the stair and its landings.
  • A handrail, and balusters or a guard on every open side.

Headroom: where stairs lose it

Headroom is measured straight up from the line joining the front edges of the steps, to the lowest thing above: the slab of the floor above, a beam at the edge of the stair opening, or the underside of the flight above. The commonest failure is a beam across the edge of the floor opening, at exactly the point where people walk under it. The next is the flight above, in a stair that turns. Both are visible on the drawings, as long as someone checks them in section, not only in plan.

At 2.2 m, most adults pass without ducking. A tall person with a raised arm or carrying a box needs more, so a little extra is worth having where the design allows.

Every step the same

People do not look at each step as they climb. The body learns the rhythm from the first two and repeats it. One step that is higher or lower than the rest, even by a centimetre or two, catches the foot. That is why the riser must be the same from bottom to top, and why the first and last steps are where most errors hide.

On site, the floor levels are often not yet finished when the stair is cast. If the stair is set out from the rough slab, and the floor finish later adds to the bottom landing and the top floor by different amounts, the first or last riser ends up a different height. The stair should be set out from the finished floor levels on both floors, with the finishes' thickness agreed before the first shutter goes up.

Count the risers and measure the floor-to-floor height on the drawing: the number of risers times the riser height must equal it exactly, with every riser the same.

Landings, handrails and balusters

  • Landings at least as deep as the stair is wide, so people can turn and pass.
  • Doors that do not open over a downward flight; a door opening onto the top step is a fall waiting to happen.
  • Winders, the pie-shaped steps in a turn, avoided on main stairs, or kept wide enough at the walking line.
  • A continuous handrail at about 900 mm above the nosings, easy to grip, on at least one side, and both sides on wide stairs.
  • Balusters or a guard on open sides, spaced so a 100 mm ball cannot pass through, so children cannot slip through or get their heads stuck.
  • No horizontal rails that children can climb like a ladder.
  • Treads with a non-slip finish, and nosings that stand out from the tread so the edge can be seen.
A stair with cast-iron balusters in an old house on Dinu Rakshit Lane, North Kolkata
A stair with cast-iron balusters in an old house on Dinu Rakshit Lane, North Kolkata. Photo: Marajozkee, CC BY-SA 4.0, via Wikimedia Commons

Stairs in buildings of flats

In a building of flats the stair is also the way out in a fire. The rules set its width, its enclosure, its doors and, in taller buildings, how many stairs there must be and how far anyone may be from one. The stair must not be blocked by storage, shoes, bicycles or locked grilles. The fire service checks stairs before issuing its recommendation for taller buildings; our fire safety guide explains it.

The structure behind the stair

A concrete stair is a sloping slab, a folded slab, or steps carried on beams or stringers. It needs its own structural design: the waist thickness, the steel and how it is supported at the landings and floors. Adding a stair to an existing building, or moving one, means cutting an opening in a slab, which is structural work. Our guide to combining two flats covers an internal stair between floors. Steel and timber stairs need their supports designed too, and steel stairs outdoors need protection from rust.

Checks on the drawing and on site

  1. On the drawing: floor-to-floor height divided by the number of risers gives the riser; check it falls inside the comfortable range and every riser is equal.
  2. Check the tread, the width and the landings against the applicable rule.
  3. Draw a section and check the headroom under every beam and every flight above.
  4. Agree the finished floor levels and the finish thicknesses before the stair is cast.
  5. On site: measure every riser and every tread before the concrete is poured, and again after the finishes go on.
  6. Check the handrail height and the baluster gaps with a tape and a 100 mm ball or block.
  7. Walk up and down the stair before it is accepted, in daylight and at night.

Check these on the drawing (and again on site)

  • Riser count × riser height must exactly equal floor-to-floor height — a 3.0m floor needs 17–19 risers, not 15 tall ones.
  • Minimum clear width: 1.0m for homes (Model Building Bye-Laws 2016 cl. 4.17.2; 0.75m only for a two-storey row house). For buildings with flats in KMC, rule 127 asks for 1.0–1.5m as the building gets taller, with wider landings.
  • Clear headroom of at least 2.2m (7 ft 3 in) everywhere on the stair and under its landings, measured up from the line of the step edges to the slab or beam above (MBBL 2016 cl. 4.17.4.2). A beam at the edge of the floor opening is where most stairs lose it.
  • Landing depth at least equal to stair width; doors must not swing over a downward flight.
  • Handrail at 900mm height, and balusters spaced so a 100mm sphere can't pass — that's the child-safety test.

Why site-built stairs go wrong

Masons set the first riser off an unfinished floor, then absorb the accumulated error in the last step. Insist the stair is set out from finished floor levels on both floors before the first shutter is fixed.

Questions people ask

What is a comfortable step height for a home?

Risers of about 150 to 190 mm with treads of about 250 to 300 mm, so that twice the riser plus the tread comes to about 580 to 640 mm.

How much headroom does a stair need?

At least 2.2 m clear, measured up from the line of the step edges to the slab, beam or flight above (Model Building Bye-Laws, 2016, clause 4.17.4.2).

How wide must a stair be?

At least 1.0 m for homes under the Model Building Bye-Laws, 2016, with 0.75 m only in a two-storey row house. In Kolkata, KMC rule 127 sets 1.0 to 1.5 m for buildings with flats, by height.

Why is one odd step dangerous?

People climb by rhythm and stop looking after the first steps. A step that is higher or lower than the others catches the foot.

Are winders allowed?

They are best avoided on main stairs. Where they are used, they should be wide enough at the walking line.

Can a staircase be added to an existing house?

Yes, with an engineer's design: it means cutting a slab opening and supporting the stair properly. It is structural work, not only carpentry or masonry.

Red flags

  • Risers that measure differently step to step
  • Winders (pie-shaped steps) squeezed in to save space on the main stair
  • Headroom under a beam that makes tall users duck

Pro tip

Adding or moving a staircase changes load paths and needs a structural check — it is never just carpentry and masonry.

Try it in our Lab: Staircase Designer

Sources

  1. Model Building Bye-Laws, 2016 (Town and Country Planning Organisation, Ministry of Housing and Urban Affairs) (checked 15 Nov 2026)
  2. The Kolkata Municipal Corporation Building Rules, 2009 (rule 127) (checked 15 Nov 2026)
  3. National Building Code of India 2016, Parts 3 and 4 (Bureau of Indian Standards) (withdrawn by BIS on 30 April 2026; replaced by the National Building Construction Standards 2026, SP 7:2026) (checked 15 Nov 2026)
  4. National Building Construction Standards 2026 (SP 7:2026), Part F Fire and Life Safety (Bureau of Indian Standards) (checked 28 Nov 2026)

Checked against these sources on the dates shown, pending our team’s sign-off.

Skip to content
KNOWLEDGE HUB · {{ nAll }} FREE FIELD GUIDES

Know before you build.

Plain-language guides from our engineering desk. No jargon without a translation and no scare tactics, just the checks and rules of thumb professionals use on site, so you can talk to any contractor, including us, as an informed client.

{{ readLine }}

{{ countTxt }}

Loading the guides
We couldn’t load the guides.The connection may have dropped. Try again, or ask Delta below: its answers come from the same guides.
No guides match “{{ q }}”.Try a broader word such as damp, cement or RERA, or ask Delta below.
DID YOU KNOW · {{ factNo }}

{{ fact }}

These guides describe standard Indian construction practice and field checks aligned with IS codes, such as IS 456 for concrete, IS 383 for aggregates and IS 1893 for seismic zoning. They are general education. Every building is different, so treat anything structural as a reason for an on-site professional assessment, not a do-it-yourself diagnosis.

Ready to plan your own build?

Five taps give you a cost range, a season plan and your area’s rules. Or send us your plot for a free preliminary estimate, usually within 48 hours.*

Start your free estimate →Plan your build in five tapsTalk on WhatsApp

*Indicative, not guaranteed. Timing varies with the complexity of your query.

{{ g.dom }}· {{ g.mins }} MIN READ
{{ g.trNote }}

{{ g.title }}

{{ g.imgAlt }}
Photo: {{ g.imgBy }}, {{ g.imgLic }}, via Wikimedia Commons
THE SHORT ANSWER

{{ s.t }}{{ s.t }}

IN PLAIN WORDS

{{ s.t }}{{ s.t }}

{{ g.dNote }}

{{ s.t }}{{ s.t }}

{{ x.h }}

{{ s.t }}{{ s.t }}

  • {{ s.t }}{{ s.t }}
  1. {{ st.n }}{{ s.t }}{{ s.t }}
{{ r.label }}{{ c.k }}{{ c.v }}
{{ fg.alt }}
Photo: {{ fg.by }}, {{ fg.lic }}, via Wikimedia Commons

{{ x.h }}

{{ s.t }}{{ s.t }}

  • {{ s.t }}{{ s.t }}
  1. {{ st.n }}{{ s.t }}{{ s.t }}
{{ r.label }}{{ c.k }}{{ c.v }}

{{ g.faqT }}

{{ f.q }}

{{ s.t }}{{ s.t }}

RED FLAGS ON SITE
  • {{ s.t }}{{ s.t }}
PRO TIP

{{ s.t }}{{ s.t }}

SEEING THIS AT HOME?{{ g.probT }}Tick what you see and we tell you what it most likely means, with the fixes ranked honestly.Check yours → {{ g.goKick }}{{ g.goName }}{{ g.goDesc }}{{ g.goCta }} PLAY · ONE MINUTE{{ g.playName }}{{ g.playLine }}Play the game →
Ask our engineers on WhatsApp
{{ g.srcHead }}
  1. {{ s.l }}{{ s.chk }}

Checked against these sources on the dates shown, pending our team’s sign-off. Rules change, so we check them again for your plot before anything is filed.