Rebar Cover Checker
Member + exposure → clear cover per IS 456
Category: Steel & repair
What you enter
- Member: Slab, Beam, Column, Footing (cast against soil)
- Exposure: Mild · protected interior, Moderate · external, rain-washed (Kolkata default), Severe · coastal / alternate wet-dry, Very severe · sea spray, aggressive
An example
With the starting values (Member: Slab; Exposure: Mild · protected interior), it gives:
- Required nominal cover: 20 mm
- Governed by: Member minimum
- Cover blocks to specify: 20 mm factory-made (tolerance +10 / −0 mm)
Good to know
IS 456 Table 16 & cl. 26.4 — cover is measured to the outermost steel (the stirrup, not the main bar). Kolkata's humid air makes Moderate the sensible default outdoors. Insist on factory cover blocks; stone chips and broken-tile spacers are how slabs rust from below.
Sources
- IS 456:2000, Table 16 and clause 26.4
Checked 7 Oct 2026, pending our team’s sign-off.
Read the guide
- Cover blocks — the 25mm that decides your building's lifespan
- Why 40-year-old RCC fails — carbonation, chlorides and rusting rebar
Free, instant and indicative: a starting point for our engineers’ estimate, not a substitute for one.