Lap & Development Length
Bar dia + grade → lap length per IS 456
Category: Steel & repair
What you enter
- Bar diameter: 8 mm, 10 mm, 12 mm, 16 mm, 20 mm, 25 mm
- Concrete grade: M20, M25, M30
- Bar state: Tension (beam / slab bottom bars), Compression (column verticals)
An example
With the starting values (Bar diameter: 8 mm; Concrete grade: M20; Bar state: Tension (beam / slab bottom bars)), it gives:
- Development length Lₑ: ≈ 455 mm (57φ)
- Recommended lap length: 460 mm
- Common site rule: 50φ = 400 mm — shorter than IS 456 asks for here: use the lap above
Good to know
IS 456 cl. 26.2 for Fe500 deformed bars. Stagger laps so no more than half the bars lap at one section, keep laps away from maximum-moment zones and beam-column joints, and never lap by simply hooking bars together — tie the full lap length. With M20 the code asks for about 57φ in tension, so the common 50φ is short; it is enough from M25. For a whole bar list with laps, cut lengths and the 12 m bars to buy, use Steel Weight and BBS in the Lab.
Sources
- IS 456:2000, clause 26.2
Checked 10 Oct 2026, pending our team’s sign-off.
Read the guide
Free, instant and indicative: a starting point for our engineers’ estimate, not a substitute for one.