Room Ventilation Checker
Room + window size → daylight check
Category: Interiors & comfort
What you enter
- Room length (ft)
- Room width (ft)
- Openable window / vent area (sq ft)
An example
With the starting values (Room length (ft): 12; Room width (ft): 10; Openable window / vent area (sq ft): 15), it gives:
- Floor area: 120 sq ft
- Required opening (1/6th of floor): 20.0 sq ft
- Provided: 15 sq ft
- Verdict: ✗ Short by 5.0 sq ft
Good to know
The National Building Code of 2016 recommended openings (windows + ventilators) of at least 1/6th of floor area for habitable rooms. NBCS 2026, which replaced it, does not repeat that share: its Part D Section 1 (cl. 5.4.3.1) notes that openings of 20 to 30% of the floor, inlet and outlet together, bring the indoor breeze to about 30% of the outdoor one, with about half the opening area below 2.25 m. Kitchens and baths have their own rules, and in Kolkata the KMC Building Rules set what a plan needs. Cross-ventilation (openings on two walls) matters as much as area in Kolkata's humidity; a single big window on one wall barely moves air.
Sources
- NBC 2016, Parts 3 and 8 (withdrawn 30 Apr 2026)
- NBCS 2026 (SP 7:2026) Part D Sec 1, cl. 5.4.3.1 (natural ventilation by wind; read 28 Nov 2026)
Checked 7 Oct 2026, pending our team’s sign-off.
Read the guide
Free, instant and indicative: a starting point for our engineers’ estimate, not a substitute for one.