On 30 April the Bureau of Indian Standards withdrew the National Building Code of 2016 and put the National Building Construction Standards 2026 in its place. In June West Bengal’s municipal building rules moved to it. What changed, which rules your plan follows in Kolkata and the towns around it, and the figures worth using now.

By Raj Sekhar Ghosh, Editor. Published 2026-11-29. Updated 2026-11-29.

Flights and landings of a stair at the Birla Industrial & Technological Museum, Kolkata
A stair at the Birla Industrial & Technological Museum, Kolkata (2012). Stairs are one of the places where the new standard’s figures differ from the 2016 code’s. Photo: Biswarup Ganguly, CC BY 3.0, via Wikimedia Commons

Key points

  • On 30 April 2026 the Bureau of Indian Standards (BIS) withdrew the National Building Code of India 2016 and, the same day, established the National Building Construction Standards 2026 (NBCS 2026, SP 7:2026) in its place, with no overlap.
  • NBCS 2026 calls itself a standard, not a code. It says “should” where the old code said “shall”, and it binds only where a state, a city or a contract adopts it.
  • It has six parts in place of twelve. Plot rules such as setbacks, coverage, room sizes and heights are no longer in it: they stay with the state’s and the city’s building rules.
  • Its fire part counts a building as high-rise from 24 m (the 2016 code: 15 m). In West Bengal the fire services still treat a building above 14.5 m as high-rise.
  • On 12 June 2026 the state put NBCS 2026 in place of the 2016 code in the West Bengal Municipal (Building) Rules, 2007, the rules of towns such as Rajpur Sonarpur and Baranagar. In KMC a plan is still checked against the KMC Building Rules, 2009.
  • For a house: we found nothing that reopens a plan already sanctioned. For new drawings, ask which edition your engineer used, and use the new figures for stairs, water tanks and roof drains.

What changed on 30 April

On 30 April 2026 the Bureau of Indian Standards published a notification in the Gazette of India (Extraordinary, No. 299) under rule 15(1) of the BIS Rules, 2018. It lists one standard established and one withdrawn: SP 7:2026, the National Building Construction Standards 2026, in, and SP 7:2016, the National Building Code of India 2016, out. A notice of this kind can let an old standard run beside the new one until a later date; here both dates are 30 April.

The national code had guided Indian building since 1970, revised in 1983, 1997, 2005 and 2016. The new name drops the word code on purpose: summaries of the change say the word was read as binding, while the new document is meant as advice for the authorities that make the rules.

A standard, not a code

The foreword of NBCS 2026 says the document is voluntary and non-binding, and that it takes effect through adoption by the authorities concerned or through a contract. Its fire part goes further: fire services are a State subject, and Part F is “only for guidance and referral” for state governments and local authorities. Throughout, the text says “should”.

So the standard does not by itself change what your municipality checks. Your plan is checked against the building rules of the body that sanctions it, and those rules decide which parts of the national standard apply. Where a rule, a tender or a contract still names the 2016 code, it names a document BIS no longer maintains.

Six parts, and what left

NBCS 2026 comes in two volumes and six parts: A Introduction, B Building Materials, C Structural Design (loads, foundations, masonry, concrete, steel, glass and more), D Building Services (lighting and ventilation, electrical, air conditioning, acoustics, lifts and escalators), E Plumbing Services (water supply, drainage, solid waste, gas) and F Fire and Life Safety. The 2016 code had twelve.

The biggest gap for a plot owner is the old Part 3, the development control rules and general building requirements: plot, setbacks, coverage, room sizes and heights. It has no part of its own in the new standard. In Kolkata those were always KMC’s and the state’s rules to set, and they still are. The old parts on construction management and site safety, landscaping and signs, sustainability and asset management no longer stand as parts of their own either.

The figures that moved

Part F counts a building as high-rise from 24 m, whatever it is used for; the 2016 code drew the line at 15 m. Its fire provisions apply to a residential building above 24 m or with more than 750 m² on any floor, and the state may change those limits. For apartment houses of up to 500 m² a floor and up to 24 m, it accepts self-certification by a state-approved building professional.

For the buildings it covers, Part F advises stair treads of at least 250 mm without the nosing in residential buildings, risers of at most 175 mm in one- or two-family dwellings and 150 mm in others, 12 risers to a flight and never more than 15, and at least 2.2 m of headroom. The 2016 code allowed a 190 mm riser in residential buildings. Ramps: no steeper than 1 in 12.

Part E puts a city home’s water at 135 litres a person a day, or 100 with water-efficient fittings. Where supply comes for a few hours a day, an apartment building stores a day and a half below ground and half a day on the roof; a house filling its roof tank from its own sump keeps half a day up top. Tanks deeper than 0.9 m get ladders that resist corrosion.

For roof drainage, Table 25 of Part E lets one 100 mm rainwater pipe drain 84 m² of roof at a rainfall of 100 mm an hour, and a 75 mm pipe about 41 m². Builders here often allow one 100 mm pipe for every 40 m² or so, which is the table’s figure for 200 mm an hour.

The fireman’s lift in a high-rise keeps the 2016 figures: at least 8 persons (544 kg), automatic doors at least 0.8 m wide, and the top floor within a minute.

In Kolkata and the towns around it

Inside KMC, a building plan is checked against the KMC Building Rules, 2009, as amended in September 2025, and a building above 14.5 m also needs the state fire services’ recommendation. We have found no order that writes NBCS 2026 into the KMC rules.

In the towns under the West Bengal Municipal (Building) Rules, 2007, from Rajpur Sonarpur and Baruipur to Baranagar and Serampore, the state moved on 12 June 2026. An order of the Department of Urban Development and Municipal Affairs replaced the references to the 2016 code in those rules with the matching provisions of NBCS 2026, with immediate effect, from fire safety in buildings above 14.5 m and structural design to lifts, ventilation, earthquake protection, water supply, drainage and gas. The department said the rules themselves would be amended in due course.

What it means if you are building a house

If your plan is already sanctioned, build to it. We found nothing in the change that reopens a sanction, and in KMC the rules it was checked against have not changed. If you are about to apply in a municipality, ask your architect or licensed building surveyor to follow NBCS 2026 wherever the 2007 rules point to the national code.

Use the new figures where they make sense for any house: stair risers of no more than 175 mm and treads of at least 250 mm, a roof tank for half a day and a sump for a day and a half at 135 litres a person, and roof drains sized from Table 25, with at least two outlets on any roof (our own rule, so one blocked drain cannot flood it). Our Water Tank Sizing tool and the roof runoff calculator now work this way; the Staircase Designer still checks the 190 mm limit of the Model Building Bye-Laws and names Part F’s figures in its sources.

If a new drawing, a specification or a quotation still says NBC 2016, ask which figure it relies on. Many figures did not change, and some did, the stair riser among them. And if you want to read the standard itself, BIS gives it free after a registration on its BSB Edge store or its Manak portal.

What we could not confirm

We read the state’s order of 12 June through the department’s own listing and a report of its contents, not the order itself, so we cannot list every rule it touches. We found no matching order for the KMC Building Rules, 2009. We read Parts D, E and F of NBCS 2026 where they touch a house, not every clause of Parts A to C. When KMC or the state publishes more, we will update this article.

What this means for you

  • Your plan in KMC is sanctioned: build to it; the KMC Building Rules, 2009 still decide what is checked.
  • You are applying in a municipality such as Rajpur Sonarpur or Baranagar: ask your architect to follow NBCS 2026 wherever the 2007 rules point to the national code.
  • You are planning a stair: risers of at most 175 mm, treads of at least 250 mm, 2.2 m of headroom.
  • You are sizing water tanks: half a day on the roof, a day and a half in the sump, at 135 litres a person.
  • You see “NBC 2016” on a new drawing or quotation: ask which figure it relies on, and whether NBCS 2026 changed it.

Sources

  1. Gazette of India, Extraordinary, Part III Sec 4, No. 299 (30 April 2026): BIS establishes SP 7:2026 and withdraws SP 7:2016 (checked 2026-11-29)
  2. Bureau of Indian Standards: SP 7:2026, National Building Construction Standards 2026: the foreword; Part F Fire and Life Safety cl. 1.2, 2.39, 4.4.2.4.3.1 to 4.4.2.4.3.5, Table 7A; Part E Plumbing Services Sec 1 cl. 4.1.1, 4.4, 4.4.10 and Sec 2 Table 25; Part D Sec 5A cl. 7.1 (free from BIS after registration) (checked 2026-11-28)
  3. Department of Urban Development and Municipal Affairs, West Bengal: What’s New, adoption of NBCS 2026 in place of NBC 2016 under the West Bengal Municipal (Building) Rules, 2007 (12 June 2026) (checked 2026-11-29)
  4. PropNewsTime: the state’s order of 12 June 2026 replacing NBC 2016 references in the municipal building rules (11 August 2026) (checked 2026-11-29)
  5. Drishti IAS: National Building Construction Standards 2026 (the code’s history and why the name changed) (checked 2026-11-29)
  6. SiteSetu: NBCS 2026, its parts, legal status and free access (checked 2026-11-29)
  7. The Kolkata Municipal Corporation Building Rules, 2009 (kmcgov.in, PDF) (checked 2026-11-18)
  8. West Bengal Fire and Emergency Services: fire safety recommendation (checked 2026-10-14)

Check it yourself

Skip to content

We can’t find that article.

It may have moved, or it is not published yet.

All news
DRAFT · NOT PUBLISHED{{ draftLine }}
  1. {{ c }}
{{ catUp }}· {{ mins }}

{{ t }}

{{ dek }}

By Raj Sekhar Ghosh, Editor{{ dateLine }}
Share on WhatsApp

Copying is blocked here. Select the link and copy it: {{ shareU }}

{{ alt }}
{{ cap }} Photo: {{ img.by }}, Wikimedia Commons, {{ img.lic }}.

{{ kpTitle }}

  • {{ k }}

পুরো লেখার বাংলা অনুবাদ রাজ শেখর ঘোষের অনুমোদনের পর ইংরেজির সঙ্গে একই দিনে প্রকাশিত হবে। নিচের অংশ এখন ইংরেজিতে।

{{ s.h }}

{{ p }}

{{ s.fig.alt }}
{{ s.fig.cap }} Photo: {{ s.fig.by }}, Wikimedia Commons, {{ s.fig.lic }}.

{{ youTitle }}

  • {{ y }}
Ask us about this on WhatsApp

Sources

{{ updLine }}

  1. {{ r.n }} · checked {{ r.c }}

We update this article when a date or a fact changes, and say what changed.

Check it yourself

FROM DELTA STRUCTURES, WHO PUBLISH NEWS

{{ endH }}

{{ endP }}

Raj Sekhar Ghosh

Editor, News · Civil Engineer, Advanced Construction Management (ACM) Professional · more than eight years in construction

More from News

The week’s news, every Saturday morning. All news and the weekly email