Electrical Load Estimator
Home size → sanctioned load & phase
Category: Engineering
What you enter
- Built-up area (sq ft)
- Air-conditioners
- Geyser + pump + kitchen?: Yes, No
An example
With the starting values (Built-up area (sq ft): 1200; Air-conditioners: 2; Geyser + pump + kitchen?: Yes), it gives:
- Connected load: ≈ 8.8 kW
- Diversified demand: ≈ 6.2 kW
- Recommended supply: 1-phase (upgrade if adding ACs)
Good to know
Rough load: about 1.5 W per sq ft for lights, fans and plug points, about 1.5 kW per AC, plus the geyser, pump and kitchen. CESC or WBSEDCL sanctions the connected load and decides single or three-phase (usually three-phase above about 7–8 kW). A licensed electrician files the actual load sheet.
Sources
- WBERC supply code for CESC and WBSEDCL
- Our electrical practice
Checked 8 Oct 2026, pending our team’s sign-off.
Read the guide
- 7 signs your home needs rewiring
- House wiring — copper gauge, MCB sizing and what 'ISI' must mean
- Switchboard heights & socket counts — the electrical plan you'll live with
Free, instant and indicative: a starting point for our engineers’ estimate, not a substitute for one.